online_cipolletti:   Calculation of discharge through a Cipolletti weir

Cipolletti weir
Formula:


Q = 3.367 L H3/2          [in U.S. Units]


Head H on the weir, in m [or ft]
Length L on the weir, in m [or ft]
Height P to the weir crest, in m [or ft]
Side width b, in m [or ft]

Discharge Q  in L/s [or cfs]

See USBR Manual for general methodology



INPUT DATA:       [Description]

Select Units:     

Head H :     
  
[ H > 0 ]
Length L :     
  
[ L > 0 ]
Height P :     
  
[ P > 0 ]
Width b :     
  
[ b > 0 ]


OUTPUT:

Warning:  Ratio P/H = 0 < 2.

Warning:  Ratio b/H = 0 < 2.

Discharge  Q :   0  



            

  Your request was processed at  02:56:22 pm on October 15th, 2024   [ 241015  14:56:22 ].


Thank you for running   online_cipolletti   Please call again.   [131027]

Count