DATA INPUT:

Clearwater Creek

Units: U.S. Customary.

Flow depth= 10 ft.

Mean velocity = 3 fps.

Channel width = 30 ft.

Measured concentration of suspended bed material = 100 ppm.



RESULTS:

Clearwater Creek

U.S. Customary Units.

Unit-width water discharge q = 30 cfs/ft

Water discharge Q = 900 cfs

Measured bed-material discharge = 8.1 tons/day/ft

Unmeasured bed-material discharge = 6.004 tons/day/ft

Total unit-width bed-material discharge qs = 14.104 tons/day/ft

Total bed-material discharge Qs = 423.115 tons/day