online_discharge_venturi_meter:  Discharge using a Venturi meter

A Venturi meter

Online head loss using Venturi meter

ν = f(T)

ReD2/K = (2gh)1/2(D2/ν)

K = f(ReD2/K, D2/D1)

A2 = (π/4) D22

Q = K A2 (2gh)1/2

[SI units: h in m; D in m; T in °C; Q in m3/s]
[U.S. units: h in ft; D in ft; T in °F; Q in cfs]



INPUT DATA:


Select:  

Head loss hρ2 :    

   

Diameter D1 :    

   

Diameter D2 :    

   

Temperature T :    

   

Ratio ρ21 :    

    [Leave blank to set mercury manometer
as default ρ21 = 13.6]

OUTPUT:

Q =  0  


Venturi effect on Wikipedia


            

  Your request was processed at  05:15:31 pm on December 30th, 2024   [ 241230  17:15:31 ].


Thank you for running online_discharge_venturi_meter.   [160721]

Count